
On this page
Key takeaways
- B1 is clean and light industry. NEA's nuisance buffer from a B1 zone is 50 metres.
- B2 is for general and special industry. The buffer from a B2 zone is 100 metres.
- Inside each strata unit, industrial use must be at least 60%. Ancillary office stops at 40%.
- A showroom can sit in that 40%. It cannot be the whole unit.
The numbers
- B1 buffer
- 50 metres
- B2 buffer
- 100 metres
- Industrial share
- At least 60% of the unit
- Ancillary office
- At most 40% of the unit
- B2 minimum unit
- 150 square metres
B1 and B2 are both industrial zones. Neither one is an office zone. The difference is the kind of industry, and how far the nuisance buffer has to sit from neighbours. The office you can put inside the unit is the same idea in both: supporting space, capped at 40%.
B1 vs B2 in one table
URA’s handbooks, read on 31 October 2026, draw the line like this.
| Business 1 | Business 2 | Business Park | Commercial | |
|---|---|---|---|---|
| What the zone is for | Clean and light industry | General and special industry, as well as clean and light | Research, high-technology manufacturing and related park uses | Offices, shops and other commercial uses |
| Nuisance buffer | 50 metres from the zone | 100 metres from the zone | Pollutive and bad-neighbour uses are not allowed in the park component | Not an industrial buffer |
| Predominant share | At least 60% | At least 60% | At least 60% of the non-White component, and at least 85% of the whole development in park use | Set by the Master Plan and the written permission |
| Ancillary share | At most 40%, including inside each strata unit | At most 40%, including inside each strata unit | At most 40% of the non-White component | Not the industrial 40% cap |
| Unit size stated by URA | Check the written permission | Minimum 150 square metres a unit | See the Business Park handbook | See the approved plan |
| Typical occupier | Light assembly, printing, food packing, listed e-business | Heavier manufacturing, warehouses, repair | Labs, product development, core media | A firm whose approved use is office |
Sources: B1 handbook, B2 handbook, B2 guidelines at a glance, Business Park use quantum.
General industry can be considered in B1 only if it meets the buffer the authority sets for that industry, and only after evaluation. Special industries such as shipbuilding are for selected B2 areas, again after evaluation. URA says it can depart from the handbook where the case warrants it, so the written permission still controls the unit in front of you.
Allowed vs not allowed uses
URA publishes example lists and says uses that are not on the list are assessed on their merits. These are the published categories, not a promise about a particular unit.
| Proposed use | Where URA places it |
|---|---|
| Light manufacturing, food packing, printing and publishing | Predominant use in B1 |
| Core media that needs studios or high-end production facilities | Predominant use in B1, B2 and Business Park |
| Software development, a data centre, an internet service provider | E-business, which URA lists as a predominant use |
| A call centre | Business Park and B1. URA says not in B2 |
| General manufacturing, chemical storage, assembly | Predominant use in B2 |
| Ancillary office, meeting room, showroom | Ancillary, maximum 40% |
| A shop, restaurant, commercial school or a bank | White component, if the site has one. Not the ordinary 60% |
| A standalone office with no industrial activity | Not allowed. The 60% has to be industrial use |
The 60:40 checker applies the share to the floor area you type in. A 1,000 square foot strata unit can put at most 400 square feet into ancillary office.
Ancillary office limits
URA’s use quantum pages, both updated 6 June 2026, say the same thing for multi-user buildings. At least 60% of the development is predominant industrial use. At least 60% of each strata unit is industrial use. Ancillary uses, and URA’s own example is “ancillary office, meeting rooms”, shall not occupy more than 40% of that unit.
Common corridors, stairs, lifts, toilets and mechanical space sit in the development-level 40%, together with the secondary uses. They do not give the unit a larger office.
A single-user building that is not strata subdivided can sub-lease, but if it sub-leases to other tenants URA applies the multi-user control, including the cap inside the space that is sub-leased.
Showrooms, e-commerce, studios, tuition
A showroom is on the ancillary list for both B1 and B2. It can be part of the 40%. It is not a reason to leave the other 60% empty, and it is not a shop. A shop is a White-component use.
E-commerce is not one URA category. The e-business uses URA actually names are a data centre that runs on heavy equipment rather than desktop computers, an internet service provider, software development, and a call centre. A call centre can be in B1 and a Business Park, and URA says it cannot be in B2. Packing and storing goods can be an industrial use if it matches the predominant list, such as packing of food or warehousing. A retail shopper experience does not become industrial because the orders arrive online.
A studio is core media only when it is production that needs technical facilities, studios and high-end hardware or software. URA allows that as part of the 60% in B1, B2 and Business Park. A room with a desk and a camera is an office, and an office is ancillary.
Tuition and a commercial school are not on the predominant or ancillary lists. URA places “office (includes bank), commercial school” in the White component. A B1 or B2 unit with no White component is the wrong building for a tuition centre unless a change of use is granted. Start with the approved-use check.
How to check a unit’s zoning
Read three documents, in this order.
- The Master Plan zoning of the land, on URA SPACE. B1, B2, Business Park and Commercial are different rows in the table above.
- The approved use of the unit. URA’s enquiry is S$54.50 including GST for one unit. If the record is already online, the reply is immediate. If URA has to search, the reply is given in 10 working days.
- If the landlord is JTC, the JTC change-of-use and subletting rules as well. URA’s 60:40 rule and JTC’s consent are separate.
The Business Park page covers park zoning. A unit that is already approved as an office in a commercial building does not use this table at all.
Get an introduction
Tell us what you need. The service below is set for this page and you can change it. Fiona replies on WhatsApp.
Thank you
Fiona has your introduction request and will reply on WhatsApp. For anyone other than her estate agency work, you choose the professional and you pay them directly.
WhatsApp FionaQuestions on this topic
What is the difference between B1 and B2 industrial?
URA puts clean and light industry in Business 1, and general and special industry in Business 2. The National Environment Agency's nuisance buffer is 50 metres from a B1 zone and 100 metres from a B2 zone. Both zones use the same 60% industrial and 40% ancillary split, including inside each strata unit.
What does light industrial B1 mean?
URA's Business 1 handbook says clean and light industries are allowed in a B1 zone. The Master Plan written statement describes B1 as clean industry, light industry, public utilities and telecommunication uses for which the authority does not impose a nuisance buffer greater than 50 metres.
What is a B1 building?
It is a building on land zoned Business 1. The zone, not the marketing name, decides the use. Check the Master Plan zoning and the approved use of the unit before you treat it as an office.
What is B1 industrial usage?
Predominant B1 uses listed by URA include light manufacturing, food packing, printing and publishing, core media production, listed e-business activities and industrial training. Ancillary uses include an office, a showroom, a meeting room, a childcare centre and a workers' dormitory, inside the 40% cap.
What is URA Business 2?
Business 2 is the zone for clean, light and general industry, warehouses and special industries such as shipbuilding in selected areas. Call centres, which URA allows in Business Park and Business 1, are not allowed in Business 2.
Get a commercial shortlist
Tell us the use, the size and when you need to move. We'll send offices, shophouses or industrial units that fit, with the reinstatement and fit-out questions flagged before you sign.
Sources
Facts on this page were checked against these sources on 31 October 2026.
- URA: Business 1 handbook ura.gov.sg, checked 31 October 2026
- URA: Business 2 handbook ura.gov.sg, checked 31 October 2026
- URA: B1 use quantum, updated 6 June 2026 ura.gov.sg, checked 31 October 2026
- URA: B2 use quantum, updated 6 June 2026 ura.gov.sg, checked 31 October 2026
- URA: B1 allowable uses ura.gov.sg, checked 31 October 2026
- URA: B2 allowable uses ura.gov.sg, checked 31 October 2026
- URA: Master Plan 2025 written statement ura.gov.sg, checked 31 October 2026
- URA: Business 2 guidelines at a glance ura.gov.sg, checked 31 October 2026
Fact-checked against HDB, IRAS, CPF, MAS.

